CLIA laboratory director rules, explained with the official text · by Sound Lab ConsultantsCall (602) 874-1311
CLIA Lab Directorsby Sound Lab Consultants
Menu
CLIA lab directors

CLIA lab director requirements, explained

The CLIA regulations set who can direct a clinical laboratory and what they must do. This site walks through every rule with the official text from 42 CFR Part 493, and Sound Lab Consultants can provide a qualified CLIA director when you need one.

  • Official 42 CFR 493 text
  • Updated for the 2024 rule
  • Director services in all 50 states
  • Moderate, high and PPM
Short answer

CLIA sets laboratory director qualifications by testing complexity: none for waived-only labs, 42 CFR 493.1357 for PPM, 493.1405 for moderate complexity and 493.1443 for high complexity. Since December 28, 2024, most non-pathologist directors need 20 CE hours, every director must be on site at least every 6 months, and one person may direct up to five labs.

Request a director →

Requirements we work to

  • CLIA · 42 CFR 493
  • CAP
  • COLA
  • The Joint Commission
  • State licensure

CLIA director rules by certificate

CertificateDirector qualificationsResponsibilitiesGuide
WaiverNone under CLIAFollow manufacturers' instructions (§ 493.15(e))Waived lab director
PPM42 CFR § 493.135742 CFR § 493.1359PPM lab director
Moderate complexity42 CFR § 493.140542 CFR § 493.1407Moderate complexity director
High complexity42 CFR § 493.144342 CFR § 493.1445High complexity director

Rules that apply to every nonwaived director

  • On-site visits: at least once every 6 months, 4 months apart, with documentation.
  • Five-lab limit: one person may direct no more than five laboratories.
  • 20 CE hours covering director responsibilities for most non-pathologist pathways.
  • State license as a director where the state requires one.
  • Notice to CMS (and any accreditor) within 30 days of a director change.

What changed in 2024

The CMS final rule of December 28, 2023 (88 FR 90039), effective December 28, 2024, rewrote the director pathways, added CE and on-site visit requirements, and grandfathered directors already serving. Details on CLIA personnel rule changes.

Need a CLIA director?

Sound Lab Consultants provides CLIA laboratory directors, interim directors and technical consultants and supervisors to labs in all 50 states. Use the form below or call (602) 874-1311.

Regulations behind this page

Every requirement on this page comes from the CLIA regulations, Title 42 Code of Federal Regulations Part 493. Open any section for the official text.

RegulationWhat it covers
42 CFR § 493.15Laboratories performing waived testsWaived tests and what a waived lab must do
42 CFR § 493.1357Standard; laboratory director qualificationsPPM laboratory director qualifications
42 CFR § 493.1405Standard; Laboratory director qualificationsModerate complexity laboratory director qualifications
42 CFR § 493.1443Standard; Laboratory director qualificationsHigh complexity laboratory director qualifications
Full text: 42 CFR § 493.15 Laboratories performing waived tests

§ 493.15 Laboratories performing waived tests. (a) Requirement. Tests for certificate of waiver must meet the descriptive criteria specified in paragraph (b) of this section. (b) Criteria. Test systems are simple laboratory examinations and procedures which— (1) Are cleared by FDA for home use; (2) Employ methodologies that are so simple and accurate as to render the likelihood of erroneous results negligible; or (3) Pose no reasonable risk of harm to the patient if the test is performed incorrectly. (c) Certificate of waiver tests. A laboratory may qualify for a certificate of waiver under section 353 of the PHS Act if it restricts the tests that it performs to one or more of the following tests or examinations (or additional tests added to this list as provided under paragraph (d) of this section) and no others: (1) Dipstick or Tablet Reagent Urinalysis (non-automated) for the following: (i) Bilirubin; (ii) Glucose; (iii) Hemoglobin; (iv) Ketone; (v) Leukocytes; (vi) Nitrite; (vii) pH; (viii) Protein; (ix) Specific gravity; and (x) Urobilinogen. (2) Fecal occult blood-non-automated; (3) Ovulation tests—visual color comparison tests for human luteinizing hormone; (4) Urine pregnancy tests—visual color comparison tests; (5) Erythrocyte sedimentation rate—non-automated; (6) Hemoglobin—copper sulfate—non-automated; (7) Blood glucose by glucose monitoring devices cleared by the FDA specifically for home use; (8) Spun microhematocrit; and (9) Hemoglobin by single analyte instruments with self-contained or component features to perform specimen/reagent interaction, providing direct measurement and readout. (d) Revisions to criteria for test categorization and the list of waived tests. HHS will determine whether a laboratory test meets the criteria listed under paragraph (b) of this section for a waived test. Revisions to the list of waived tests approved by HHS will be published in the Federal Register in a notice with opportunity for comment. (e) Laboratories eligible for a certificate of waiver must— (1) Follow manufacturers' instructions for performing the test; and (2) Meet the requirements in subpart B, Certificate of Waiver, of this part. [57 FR 7139, Feb. 28, 1992, as amended at 58 FR 5221, Jan. 19, 1993; 82 FR 48773, Oct. 20, 2017]

Source: eCFR, Title 42, Part 493, current as of November 24, 2026.

Full text: 42 CFR § 493.1357 Standard; laboratory director qualifications

§ 493.1357 Standard; laboratory director qualifications. The laboratory director must be qualified to manage and direct the laboratory personnel and the performance of PPM procedures as specified in § 493.19(c) and must be eligible to be an operator of a laboratory within the requirements of subpart R of this part. (a) The laboratory director must possess a current license as a laboratory director issued by the State in which the laboratory is located, if the licensing is required. (b) The laboratory director must meet one of the following requirements: (1) Be a physician, as defined in § 493.2. (2) Be a midlevel practitioner, as defined in § 493.2, authorized by a State to practice independently in the State in which the laboratory is located. (3) Be a dentist, as defined in § 493.2.

Source: eCFR, Title 42, Part 493, current as of November 24, 2026.

Full text: 42 CFR § 493.1405 Standard; Laboratory director qualifications

§ 493.1405 Standard; Laboratory director qualifications. The laboratory director must be qualified to manage and direct the laboratory personnel and the performance of moderate complexity tests and must be eligible to be an operator of a laboratory within the requirements of subpart R of this part. (a) The laboratory director must possess a current license as a laboratory director issued by the State in which the laboratory is located, if such licensing is required; and (b) The laboratory director must— (1)(i) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located; and (ii) Be certified in anatomic or clinical pathology, or both, by the American Board of Pathology or the American Osteopathic Board of Pathology; or (2)(i) Be a doctor of medicine, doctor of osteopathy, or doctor of podiatric medicine licensed to practice medicine, osteopathy, or podiatry in the State in which the laboratory is located; and (ii) Have had laboratory training or experience consisting of: (A) At least 1 year directing or supervising nonwaived laboratory testing; and (B) Have at least 20 CE credit hours in laboratory practice that cover the laboratory director responsibilities defined in § 493.1407; or (3)(i)(A) Hold an earned doctoral degree in a chemical, biological, clinical or medical laboratory science or medical technology from an accredited institution; or (B) Hold an earned doctoral degree; and ( 1 ) Have at least 16 semester hours of doctoral level coursework in biology, chemistry, medical technology (MT), clinical laboratory science (CLS), or medical laboratory science (MLS); or ( 2 ) An approved thesis or research project in biology/chemistry/MT/CLS/MLS related to laboratory testing for the diagnosis, prevention, or treatment of any disease or impairment of, or the assessment of the health of, human beings; and (ii) Have at least 20 CE credit hours in laboratory practice that cover the laboratory director responsibilities defined in § 493.1407; and (A) Be certified and continue to be certified by a board approved by HHS; and (B) Have had at least 1 year of experience directing or supervising nonwaived laboratory testing; or (4)(i)(A) Have earned a master's degree in a chemical, biological, clinical or medical laboratory science or medical technology from an accredited institution; or (B)( 1 ) Meet bachelor's degree equivalency; and (2) Have at least 16 semester hours of additional graduate level coursework in biology, chemistry, medical technology, clinical or medical laboratory science; or (C)( 1 ) Meet bachelor's degree equivalency; and ( 2 ) Have at least 16 semester hours in a combination of graduate level coursework in biology, chemistry, medical technology, clinical or medical laboratory science and an approved thesis or research project related to laboratory testing for the diagnosis, prevention, or treatment of any disease or impairment of, or the assessment of the health of, human beings; and (ii) Have at least 1 year of laboratory training or experience, or both, in nonwaived testing; and (iii) Have at least 1 year of supervisory laboratory experience in nonwaived testing; and (iv) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1407; or (5)(i)(A) Have earned a bachelor's degree in a chemical, biological, clinical or medical laboratory science or medical technology from an accredited institution; or (B) At least 120 semester hours, or equivalent, from an accredited institution that, at a minimum, includes either— ( 1 ) Forty-eight (48) semester hours of medical laboratory science or medical laboratory technology courses; or ( 2 ) Forty-eight (48) semester hours of science courses that include— ( i ) Twelve (12) semester hours of chemistry, which must include general chemistry and biochemistry or organic chemistry; ( ii ) Twelve (12) semester hours of biology, which must include general biology and molecular biology, cell biology or genetics; and ( iii ) Twenty-four (24) semester hours of chemistry, biology, or medical laboratory science or medical laboratory technology in any combination; and (ii) Have at least 2 years of laboratory training or experience, or both, in nonwaived testing; and (iii) Have at least 2 years of supervisory laboratory experience in nonwaived testing; and (iv) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1407. (6) Notwithstanding any other provision of this section, an individual is considered qualified as a laboratory director of moderate complexity testing under this section if they were qualified and serving as a laboratory director of moderate complexity testing in a CLIA-certified laboratory as of December 28, 2024, and have done so continuously since December 28, 2024. [57 FR 7172, Feb. 28, 1992, as amended at 58 FR 5233, Jan. 19, 1993; 88 FR 90039, Dec. 28, 2023]

Source: eCFR, Title 42, Part 493, current as of November 24, 2026.

Full text: 42 CFR § 493.1443 Standard; Laboratory director qualifications

§ 493.1443 Standard; Laboratory director qualifications. The laboratory director must be qualified to manage and direct the laboratory personnel and performance of high complexity tests and must be eligible to be an operator of a laboratory within the requirements of subpart R. (a) The laboratory director must possess a current license as a laboratory director issued by the State in which the laboratory is located, if such licensing is required; and (b) The laboratory director must— (1)(i) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located; and (ii) Be certified in anatomic or clinical pathology, or both, by the American Board of Pathology or the American Osteopathic Board of Pathology; or (2)(i) Be a doctor of medicine, a doctor of osteopathy, or doctor of podiatric medicine licensed to practice medicine, osteopathy, or podiatry in the State in which the laboratory is located; and (ii) Have at least 2 years of experience directing or supervising high complexity testing; and (iii) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1445; or (3)(i)(A) Hold an earned doctoral degree in a chemical, biological, clinical or medical laboratory science or medical technology from an accredited institution; or (B) Hold an earned doctoral degree; and ( 1 ) Have at least 16 semester hours of doctoral level coursework in biology, chemistry, medical technology (MT), clinical laboratory science (CLS), or medical laboratory science (MLS); or ( 2 ) An approved thesis or research project in biology/chemistry/MT/CLS/MLS related to laboratory testing for the diagnosis, prevention, or treatment of any disease or impairment of, or the assessment of the health of, human beings; and (ii) Be certified and continue to be certified by a board approved by HHS; and (iii) Have at least 2 years of: (A) Laboratory training or experience, or both: and (B) Laboratory experience directing or supervising high complexity testing; and (iv) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1445; or (4) Notwithstanding any other provision of this section, an individual is considered qualified as a laboratory director of high complexity testing under this section if they were qualified and serving as a laboratory director of high complexity testing in a CLIA-certified laboratory as of December 28, 2024, and have done so continuously since December 28, 2024. (5) For the subspecialty of oral pathology, be certified by the American Board of Oral Pathology, American Board of Pathology, or the American Osteopathic Board of Pathology. [57 FR 7172, Feb. 28, 1992, as amended at 58 FR 5234, Jan. 19, 1993; 59 FR 62609, Dec. 6, 1994; 62 FR 25858, May 12, 1997; 63 FR 55034, Oct. 14, 1998; 65 FR 82944, Dec. 29, 2000; 68 FR 3713, Jan. 24, 2003; 88 FR 90041, Dec. 28, 2023]

Source: eCFR, Title 42, Part 493, current as of November 24, 2026.

FAQ

Common questions

What does CLIA stand for?

The Clinical Laboratory Improvement Amendments of 1988, implemented in 42 CFR Part 493 and administered by CMS with CDC and FDA.

Where are the CLIA director rules?

42 CFR Part 493 Subpart M: 493.1357 and 493.1359 for PPM, 493.1405 and 493.1407 for moderate complexity, 493.1443 and 493.1445 for high complexity.

Does a waived lab need a qualified director?

No CLIA qualifications apply to waived-only labs, but the certificate still names a director.

Get a laboratory director

Tell us about your lab

Send the form and a Sound Lab Consultants team member replies within one business day with director options for your state, test menu and complexity.

Request a lab director

No obligation. Your details go only to Sound Lab Consultants.

Prefer to talk now? Call (602) 874-1311.

✓

Thank you. We have your request.

A Sound Lab Consultants team member will reply within one business day. To skip the wait, book a call now

Need a qualified laboratory director?

Sound Lab Consultants provides CLIA laboratory directors for waived, PPM, moderate and high complexity labs in all 50 states.